{"product_id":"brkr-3va41-12p-100a-35ka-ftfm-ld-lug","title":"BRKR 3VA41 1(2)P 100A 35KA FTFM LD LUG","description":"\u003ch2\u003eBRKR 3VA41 1(2)P 100A 35KA FTFM LD LUG Molded Case Circuit Breaker\u003c\/h2\u003e\n\n\u003cp\u003eThe Siemens 3VA41 molded case circuit breaker is designed for reliable system protection in electrical distribution and switchgear applications. It features a thermal-magnetic trip unit (TM210) with fixed overload and short-circuit protection, suitable for use by electrical distributors and lighting solutions providers requiring robust wire and cable protection. This device supports 1-pole operation with a rated current of 100 A and complies with UL 489 standards for heating, air conditioning, and refrigeration circuit breakers (HACR type).\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufacturer: Siemens\u003c\/li\u003e\n  \u003cli\u003eManufacturer Part #: 3VA4110-5ED54-0AA0\u003c\/li\u003e\n  \u003cli\u003eProduct Type: Molded-case circuit breaker\u003c\/li\u003e\n  \u003cli\u003eFrame Size: 3VA41 UL Frame 125\u003c\/li\u003e\n  \u003cli\u003eNumber of Poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated Current: 100 A at 40 ¬∞C\u003c\/li\u003e\n  \u003cli\u003eBreaking Capacity (UL 489): 35 kA at 277 V, 25 kA at 277 V (per product description), 14 kA at 600Y\/347 V\u003c\/li\u003e\n  \u003cli\u003eTrip Unit: Thermal-magnetic TM210 with fixed Ir and Ii\u003c\/li\u003e\n  \u003cli\u003eOperating Voltage (Rated): 480 V AC\u003c\/li\u003e\n  \u003cli\u003ePower Loss: 7.6 W per pole at rated current\u003c\/li\u003e\n  \u003cli\u003eMechanical Service Life: 15,000 operating cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical Endurance: 8,000 cycles at 480 V, 4,000 cycles at 600 V\u003c\/li\u003e\n  \u003cli\u003eConnection Type: Load side lugs installed only, low tab infeed side, circular conductor connection on output side\u003c\/li\u003e\n  \u003cli\u003eConnectable Conductor Size: 1 x (8 AWG - 3\/0) stranded round conductor\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 2.28 in x 5.31 in x 6.61 in (width x height x length)\u003c\/li\u003e\n  \u003cli\u003eProtection Class IP: IP40 (front)\u003c\/li\u003e\n  \u003cli\u003eAmbient Operating Temperature Range: -25 ¬∞C to 70 ¬∞C\u003c\/li\u003e\n  \u003cli\u003eWeight: Approximately 1.11 lbs (0.426 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit providing reliable overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eFixed overload (Ir) and short-circuit (Ii) settings for consistent performance\u003c\/li\u003e\n  \u003cli\u003eUL listed HACR type breaker suitable for heating, air conditioning, and refrigeration applications\u003c\/li\u003e\n  \u003cli\u003eCompact dimensions optimized for space-efficient panel installations\u003c\/li\u003e\n  \u003cli\u003eRobust mechanical and electrical endurance for extended service life\u003c\/li\u003e\n  \u003cli\u003eLoad side lug installation simplifies wiring configuration\u003c\/li\u003e\n  \u003cli\u003eSuitable for use in low voltage electrical distribution and switchgear assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads \u0026amp; Links\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/d91c135f46bb7e9e9683707a8c69467660a9391b.pdf?did=4169\u0026amp;pid=17827835\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e3D Image\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/923815da36a78176038827da1de8f50b0e72494e.pdf?did=4169\u0026amp;pid=17827835\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSpec Sheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/f4c878d7ca1be3ee6cecfd481f027ab0716bfe62?did=4169\u0026amp;pid=17827835\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I compare devices in TIA-Selection-Tool?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/3a51979fc769d63fb6fa23eefc5e9aff0c4a736f?did=4169\u0026amp;pid=17827835\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eWhat is the significance of the IP protection class?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8eb999d4484c1155abefecfb932e458153df814d?did=4169\u0026amp;pid=17827835\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I use the data matrix code correctly?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8a4547960986b04dfcc0e63d077619aa9e3060dd?did=4169\u0026amp;pid=17827835\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eShort-circuit current rating (SCCR) in industrial control panels?\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":48750880817407,"sku":"397701","price":546.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/5868\/6463\/files\/957cb9fff0804a744293efc1b14d37e1763cabf3-large.png?v=1782716868","url":"https:\/\/hunkshome.com\/products\/brkr-3va41-12p-100a-35ka-ftfm-ld-lug","provider":"HunksHome®","version":"1.0","type":"link"}