{"product_id":"brkr-3va41-12p-20a-25ka-ftfm-ld-lug","title":"BRKR 3VA41 1(2)P 20A 25KA FTFM LD LUG","description":"\u003ch2\u003eBRKR 3VA41 1(2)P 20A 25KA FTFM LD LUG Molded Case Circuit Breaker\u003c\/h2\u003e\n\n\u003cp\u003eThe Siemens 3VA41 molded case circuit breaker is designed for reliable line protection in electrical distribution systems. It features a thermal-magnetic trip unit (TM210) with fixed overload (Ir) and short-circuit (Ii) protection settings, suitable for use by electrical distributors and switchgear suppliers. This device supports switching duties in heating, air conditioning, refrigeration (HACR), and high-intensity discharge (HID) applications, providing robust protection for wire and cable installations in commercial and industrial lighting solutions.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufacturer: Siemens\u003c\/li\u003e\n  \u003cli\u003eManufacturer Part #: 3VA4120-4ED54-0AA0\u003c\/li\u003e\n  \u003cli\u003eFrame Size: 3VA41 Frame 125\u003c\/li\u003e\n  \u003cli\u003ePoles: 1 (1 or 2-pole configuration)\u003c\/li\u003e\n  \u003cli\u003eRated Current: 20 A at 40 ¬∞C\u003c\/li\u003e\n  \u003cli\u003eBreaking Capacity: 25 kA at 277 V, 14 kA at 347 V, 65 kA at 120 V (UL 489)\u003c\/li\u003e\n  \u003cli\u003eTrip Unit: TM210 Thermal-Magnetic, fixed Ir and Ii\u003c\/li\u003e\n  \u003cli\u003eOperating Voltage: Rated up to 480 V AC\u003c\/li\u003e\n  \u003cli\u003eConnection Type: Load side only lugs installed; low tab input, circular conductor output\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 2 in x 5.09 in x 2.96 in (50.8 mm x 129.4 mm x 75.1 mm)\u003c\/li\u003e\n  \u003cli\u003ePower Loss: 2.8 W per pole at rated current\u003c\/li\u003e\n  \u003cli\u003eMechanical Service Life: 15,000 operating cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical Endurance: 8,000 cycles at 480 V, 4,000 cycles at 600 V\u003c\/li\u003e\n  \u003cli\u003eProtection Class: IP40 (front)\u003c\/li\u003e\n  \u003cli\u003eAmbient Operating Temperature: -25 ¬∞C to 70 ¬∞C\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.426 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit with fixed overload and short-circuit settings for consistent protection\u003c\/li\u003e\n  \u003cli\u003eUL 489 certified with HACR, HID, and switching duty ratings for versatile application\u003c\/li\u003e\n  \u003cli\u003eCompact design with standardized dimensions for easy integration in switchgear and panelboards\u003c\/li\u003e\n  \u003cli\u003eLoad side only lug installation simplifies wiring and enhances safety\u003c\/li\u003e\n  \u003cli\u003eRobust breaking capacity class S for reliable interruption of fault currents\u003c\/li\u003e\n  \u003cli\u003eSuitable for use in electrical distribution systems requiring dependable circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads \u0026amp; Links\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/4ab356354eec8887f834c7718ec8517461e260b3.pdf?did=4169\u0026amp;pid=17828389\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSpec Sheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/d91c135f46bb7e9e9683707a8c69467660a9391b.pdf?did=4169\u0026amp;pid=17828389\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e3D Image\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8a4547960986b04dfcc0e63d077619aa9e3060dd?did=4169\u0026amp;pid=17828389\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eShort-circuit current rating (SCCR) in industrial control panels?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/3a51979fc769d63fb6fa23eefc5e9aff0c4a736f?did=4169\u0026amp;pid=17828389\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eWhat is the significance of the IP protection class?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/f4c878d7ca1be3ee6cecfd481f027ab0716bfe62?did=4169\u0026amp;pid=17828389\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I compare devices in TIA-Selection-Tool?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8eb999d4484c1155abefecfb932e458153df814d?did=4169\u0026amp;pid=17828389\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I use the data matrix code correctly?\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":48750881276159,"sku":"396496","price":437.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/5868\/6463\/files\/957cb9fff0804a744293efc1b14d37e1763cabf3-large_e4da8fa0-86ad-405c-a467-7c27feef6f32.png?v=1782716883","url":"https:\/\/hunkshome.com\/products\/brkr-3va41-12p-20a-25ka-ftfm-ld-lug","provider":"HunksHome®","version":"1.0","type":"link"}