{"product_id":"brkr-3va41-12p-20a-65ka-ftfm-ld-lug","title":"BRKR 3VA41 1(2)P 20A 65KA FTFM LD LUG","description":"\u003ch2\u003eBRKR 3VA41 1(2)P 20A 65KA FTFM LD LUG Molded Case Circuit Breaker\u003c\/h2\u003e\n\n\u003cp\u003eThis Siemens 3VA41 molded case circuit breaker is designed for low voltage electrical distribution and protection applications. It features a thermal-magnetic trip unit (TM210) with fixed overload and short-circuit protection, suitable for switchgear suppliers and electrical distributors requiring reliable line protection. The breaker supports 1-pole configurations and is rated for 20A operational current with a high breaking capacity, making it appropriate for industrial and commercial lighting solutions and wire and cable protection.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufacturer: Siemens\u003c\/li\u003e\n  \u003cli\u003eManufacturer Part #: 3VA4120-6ED54-0AA0\u003c\/li\u003e\n  \u003cli\u003eNumber of Poles: 1\u003c\/li\u003e\n  \u003cli\u003eCurrent Rating: 20 A\u003c\/li\u003e\n  \u003cli\u003eBreaking Capacity (UL 489): 65 kA at 277 V, 14 kA at 600Y\/347 V, 50 kA at 277 V\u003c\/li\u003e\n  \u003cli\u003eFrame Size: 3VA41 Frame 125\u003c\/li\u003e\n  \u003cli\u003eTrip Unit: Thermal-Magnetic TM210, fixed Ir and Ii\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 5.31 in x 2.28 in x 6.61 in\u003c\/li\u003e\n  \u003cli\u003eWeight: 1.11 lbs (0.426 kg)\u003c\/li\u003e\n  \u003cli\u003eOperating Voltage: Rated up to 415 V AC\u003c\/li\u003e\n  \u003cli\u003ePower Loss: 2.8 W per pole at rated current\u003c\/li\u003e\n  \u003cli\u003eConnection Type: Load side lug terminals only, tin-plated circular conductor connection on output side, low tab on input side\u003c\/li\u003e\n  \u003cli\u003eProtection Class: IP40 on the front\u003c\/li\u003e\n  \u003cli\u003eOperating Temperature Range: -25 ¬∞C to 70 ¬∞C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit for combined overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eFixed settings for overload (Ir=20 A) and short-circuit (Ii=15 x In)\u003c\/li\u003e\n  \u003cli\u003eHigh breaking capacity class H for reliable interruption of fault currents\u003c\/li\u003e\n  \u003cli\u003eDesigned for heating, air conditioning, refrigeration (HACR) and high-intensity discharge (HID) applications\u003c\/li\u003e\n  \u003cli\u003eDurable mechanical service life of approximately 15,000 operating cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance of 8,000 cycles at 480 V and 4,000 cycles at 600 V\u003c\/li\u003e\n  \u003cli\u003eLoad side lug terminals installed for secure conductor connection\u003c\/li\u003e\n  \u003cli\u003eCompact dimensions suitable for integration in switchgear assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads \u0026amp; Links\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/3a51979fc769d63fb6fa23eefc5e9aff0c4a736f?did=4169\u0026amp;pid=17827810\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eWhat is the significance of the IP protection class?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8a4547960986b04dfcc0e63d077619aa9e3060dd?did=4169\u0026amp;pid=17827810\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eShort-circuit current rating (SCCR) in industrial control panels?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/d91c135f46bb7e9e9683707a8c69467660a9391b.pdf?did=4169\u0026amp;pid=17827810\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e3D Image\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/f4c878d7ca1be3ee6cecfd481f027ab0716bfe62?did=4169\u0026amp;pid=17827810\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I compare devices in TIA-Selection-Tool?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8eb999d4484c1155abefecfb932e458153df814d?did=4169\u0026amp;pid=17827810\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I use the data matrix code correctly?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/e788c79d92d80b9d71af79080af0984933c13c0a.pdf?did=4169\u0026amp;pid=17827810\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTechnical data sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":48750881341695,"sku":"397788","price":662.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/5868\/6463\/files\/957cb9fff0804a744293efc1b14d37e1763cabf3-large_355a8c65-624a-443b-a55d-b15ad3b3a7e0.png?v=1782716886","url":"https:\/\/hunkshome.com\/products\/brkr-3va41-12p-20a-65ka-ftfm-ld-lug","provider":"HunksHome®","version":"1.0","type":"link"}