{"product_id":"brkr-3va41-1p-25a-25ka-ftfm-nav-ld-lug","title":"BRKR 3VA41 1P 25A 25KA FTFM NAV LD LUG","description":"\u003ch2\u003eBRKR 3VA41 1P 25A 25KA FTFM NAV LD LUG Molded Case Circuit Breaker\u003c\/h2\u003e\n\n\u003cp\u003eThe Siemens 3VA41 molded case circuit breaker is designed for reliable electrical protection in industrial and commercial applications. It features a thermal-magnetic trip unit (TM210) with fixed overload and short-circuit settings, suitable for use by electrical distributors and switchgear suppliers. This 1-pole breaker supports a 25A rated current with a breaking capacity of up to 25 kA at 277V, making it appropriate for wire and cable protection in lighting solutions and other electrical installations. Its naval rating and temperature rating of 50¬∞C enable operation in specialized environments.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufacturer: Siemens\u003c\/li\u003e\n  \u003cli\u003eManufacturer Part #: 3VA4125-4ED14-1AA0\u003c\/li\u003e\n  \u003cli\u003eNumber of Poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated Current: 25 A\u003c\/li\u003e\n  \u003cli\u003eBreaking Capacity: 25 kA at 277 V, 14 kA at 347 V, 65 kA at 120 V\u003c\/li\u003e\n  \u003cli\u003eTrip Unit Type: TM210 Thermal-Magnetic\u003c\/li\u003e\n  \u003cli\u003eFrame Size: 3VA41 UL Frame 125\u003c\/li\u003e\n  \u003cli\u003eOperating Voltage: 480 V AC rated\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 1 in x 5.09 in x 2.96 in (25.4 mm x 129.4 mm x 75.1 mm)\u003c\/li\u003e\n  \u003cli\u003eConnection Type: Load side lugs installed, circular conductor connection on output side, low tab on input side\u003c\/li\u003e\n  \u003cli\u003eProtection Class: IP40 (front)\u003c\/li\u003e\n  \u003cli\u003eAmbient Operating Temperature Range: -25 ¬∞C to 70 ¬∞C\u003c\/li\u003e\n  \u003cli\u003eMechanical Service Life: 15,000 operating cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical Endurance: 8,000 cycles at 480 V, 4,000 cycles at 600 V\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.28 kg (0.75 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eStandard (Class S) breaking capacity for reliable short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eFixed overload (Ir) and short-circuit (Ii) protection settings for consistent performance\u003c\/li\u003e\n  \u003cli\u003eNaval rated for specialized applications at 50 ¬∞C ambient temperature\u003c\/li\u003e\n  \u003cli\u003eHACR and HID type load switch compliant for HVAC and high-intensity discharge circuits\u003c\/li\u003e\n  \u003cli\u003eTin-plated electrical connections for corrosion resistance\u003c\/li\u003e\n  \u003cli\u003eCompact design suitable for integration in switchgear and panelboards\u003c\/li\u003e\n  \u003cli\u003eNo auxiliary contacts or motor drive options, focusing on core circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads \u0026amp; Links\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/3a51979fc769d63fb6fa23eefc5e9aff0c4a736f?did=4169\u0026amp;pid=17828429\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eWhat is the significance of the IP protection class?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/689c97c4a8acf4ad33636f062e157acc98e49c56.pdf?did=4169\u0026amp;pid=17828429\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSpec Sheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/1e389243bf1c1a394bffbd8906be1beca9b3110c.pdf?did=4169\u0026amp;pid=17828429\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e3D Image\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8eb999d4484c1155abefecfb932e458153df814d?did=4169\u0026amp;pid=17828429\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I use the data matrix code correctly?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8a4547960986b04dfcc0e63d077619aa9e3060dd?did=4169\u0026amp;pid=17828429\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eShort-circuit current rating (SCCR) in industrial control panels?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/f4c878d7ca1be3ee6cecfd481f027ab0716bfe62?did=4169\u0026amp;pid=17828429\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I compare devices in TIA-Selection-Tool?\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":48750885503231,"sku":"396498","price":304.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/5868\/6463\/files\/08d912890825691d41cb2a6edd1bdb04186892c1-large_d9dd9cfe-5502-4f7b-a25d-4f8f715c2f16.png?v=1782716996","url":"https:\/\/hunkshome.com\/products\/brkr-3va41-1p-25a-25ka-ftfm-nav-ld-lug","provider":"HunksHome®","version":"1.0","type":"link"}