{"product_id":"brkr-3va41-1p-35a-35ka-ftfm-ld-lug","title":"BRKR 3VA41 1P 35A 35KA FTFM LD LUG","description":"\u003ch2\u003eBRKR 3VA41 1P 35A 35KA Molded Case Circuit Breaker\u003c\/h2\u003e\n\n\u003cp\u003eThe Siemens 3VA41 1-pole molded case circuit breaker is designed for reliable overload and short-circuit protection in electrical distribution systems. Suitable for use by electrical distributors and switchgear suppliers, it supports line protection with a thermal-magnetic trip unit (TM210) and is ideal for applications requiring medium breaking capacity and precise current interruption.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufacturer: Siemens\u003c\/li\u003e\n  \u003cli\u003eManufacturer Part #: 3VA4135-5ED14-0AA0\u003c\/li\u003e\n  \u003cli\u003eFrame: 3VA41\u003c\/li\u003e\n  \u003cli\u003ePoles: 1\u003c\/li\u003e\n  \u003cli\u003eRated Current (In): 35 A\u003c\/li\u003e\n  \u003cli\u003eBreaking Capacity (Class M): 35 kA at 277 V\u003c\/li\u003e\n  \u003cli\u003eUL Current Breaking Capacity: 85 kA at 120 V, 35 kA at 277 V, 18 kA at 347 V\u003c\/li\u003e\n  \u003cli\u003eOvercurrent Release: TM210 thermal-magnetic trip unit with fixed Ir and Ii\u003c\/li\u003e\n  \u003cli\u003eOperating Voltage Rated Value: 415 V AC\u003c\/li\u003e\n  \u003cli\u003ePower Loss per Pole: 3.2 W\u003c\/li\u003e\n  \u003cli\u003eMechanical Service Life: 15,000 operating cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical Endurance: 8,000 cycles at 480 V, 4,000 cycles at 600 V\u003c\/li\u003e\n  \u003cli\u003eConnection Type: Load side lugs only; low tab infeed; circular conductor connection on output side\u003c\/li\u003e\n  \u003cli\u003eConnectable Conductor Cross-Section: 14 AWG to 8 AWG stranded round conductors\u003c\/li\u003e\n  \u003cli\u003eProtection Class (Front): IP40\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 1 in x 5.09 in x 2.96 in (25.4 mm x 129.4 mm x 75.1 mm)\u003c\/li\u003e\n  \u003cli\u003eAmbient Operating Temperature Range: -25 ¬∞C to 70 ¬∞C\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.28 kg (approx. 0.75 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit (TM210) provides reliable overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eMedium (Class M) breaking capacity suitable for a wide range of electrical distribution applications\u003c\/li\u003e\n  \u003cli\u003eSingle-pole design for compact installation in panelboards and switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eUL Listed and compliant with UL 489 standards for HACR and HID circuit breakers\u003c\/li\u003e\n  \u003cli\u003eFixed overload and short-circuit protection settings for consistent performance\u003c\/li\u003e\n  \u003cli\u003eLoad side lug installation ensures secure and straightforward wiring\u003c\/li\u003e\n  \u003cli\u003eRobust mechanical and electrical endurance supports long service life in demanding environments\u003c\/li\u003e\n  \u003cli\u003eSuitable for use by electrical distributors and lighting solutions providers requiring reliable wire and cable protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads \u0026amp; Links\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/3a51979fc769d63fb6fa23eefc5e9aff0c4a736f?did=4169\u0026amp;pid=17827415\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eWhat is the significance of the IP protection class?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/736c6d5c5425f11b0ab8dfd82c0a26bd5f7af9d3.pdf?did=4169\u0026amp;pid=17827415\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTechnical data sheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8eb999d4484c1155abefecfb932e458153df814d?did=4169\u0026amp;pid=17827415\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I use the data matrix code correctly?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/6cc1eb55c6e7bc0e7acbaf04e55746190f39ba1b.pdf?did=4169\u0026amp;pid=17827415\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e3D Image\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/f4c878d7ca1be3ee6cecfd481f027ab0716bfe62?did=4169\u0026amp;pid=17827415\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I compare devices in TIA-Selection-Tool?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8a4547960986b04dfcc0e63d077619aa9e3060dd?did=4169\u0026amp;pid=17827415\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eShort-circuit current rating (SCCR) in industrial control panels?\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":48750886486271,"sku":"397648","price":303.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/5868\/6463\/files\/2ae32c943ed16ea841a3ed9fc70c7dbdbdde6c68-large_e9eb69af-eb9b-44d4-af9d-160ba373420d.png?v=1782717023","url":"https:\/\/hunkshome.com\/products\/brkr-3va41-1p-35a-35ka-ftfm-ld-lug","provider":"HunksHome®","version":"1.0","type":"link"}