{"product_id":"brkr-3va41-1p-35a-65ka-ftfm-ld-lug","title":"BRKR 3VA41 1P 35A 65KA FTFM LD LUG","description":"\u003ch2\u003eBRKR 3VA41 1P 35A 65KA FTFM LD LUG Molded Case Circuit Breaker\u003c\/h2\u003e\n\n\u003cp\u003eThe Siemens 3VA41 molded case circuit breaker is designed for reliable system protection in electrical distribution and lighting solutions. This single-pole breaker features a thermal-magnetic trip unit (TM210) with fixed overload and short-circuit settings, suitable for applications requiring precise line protection and high breaking capacity. It is ideal for use by electrical distributors and switchgear suppliers managing wire and cable systems up to 480 V.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufacturer: Siemens\u003c\/li\u003e\n  \u003cli\u003eManufacturer Part #: 3VA4135-6ED14-0AA0\u003c\/li\u003e\n  \u003cli\u003eNumber of Poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated Current: 35 A at 40 ¬∞C\u003c\/li\u003e\n  \u003cli\u003eBreaking Capacity: 65 kA at 277 V, 14 kA at 600Y\/347 V\u003c\/li\u003e\n  \u003cli\u003eOverload Protection: Fixed Ir = 35 A\u003c\/li\u003e\n  \u003cli\u003eShort-Circuit Protection: Fixed Ii = 10 x In\u003c\/li\u003e\n  \u003cli\u003eOperating Voltage: 480 V AC rated\u003c\/li\u003e\n  \u003cli\u003ePower Loss: 3.2 W per pole at rated current\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 1 in x 5.09 in x 2.96 in (25.4 mm x 129.4 mm x 75.1 mm)\u003c\/li\u003e\n  \u003cli\u003eConnection Type: Load side lugs installed, circular conductor connection on output side\u003c\/li\u003e\n  \u003cli\u003eType of Electrical Connection: Low tab on infeed side\u003c\/li\u003e\n  \u003cli\u003eProtection Class (Front): IP40\u003c\/li\u003e\n  \u003cli\u003eAmbient Operating Temperature: -25 ¬∞C to 70 ¬∞C\u003c\/li\u003e\n  \u003cli\u003eMechanical Service Life: 15,000 operating cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical Endurance: 8,000 cycles at 480 V, 4,000 cycles at 600 V\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.28 kg (0.75 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit (TM210) with fixed overload and short-circuit settings for reliable protection\u003c\/li\u003e\n  \u003cli\u003eHigh breaking capacity class H suitable for demanding electrical distribution applications\u003c\/li\u003e\n  \u003cli\u003eCompact design with lugs installed on load side only for simplified wiring\u003c\/li\u003e\n  \u003cli\u003eUL listed and compliant with UL 489 standards for HACR and HID circuit breakers\u003c\/li\u003e\n  \u003cli\u003eSuitable for use in heating, air conditioning, and refrigeration circuits\u003c\/li\u003e\n  \u003cli\u003eDurable tin-plated connections for corrosion resistance and long-term reliability\u003c\/li\u003e\n  \u003cli\u003eDesigned for use in electrical distributor environments requiring robust switchgear components\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads \u0026amp; Links\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8a4547960986b04dfcc0e63d077619aa9e3060dd?did=4169\u0026amp;pid=17828669\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eShort-circuit current rating (SCCR) in industrial control panels?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/6cc1eb55c6e7bc0e7acbaf04e55746190f39ba1b.pdf?did=4169\u0026amp;pid=17828669\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e3D Image\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/f4c878d7ca1be3ee6cecfd481f027ab0716bfe62?did=4169\u0026amp;pid=17828669\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I compare devices in TIA-Selection-Tool?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/3a51979fc769d63fb6fa23eefc5e9aff0c4a736f?did=4169\u0026amp;pid=17828669\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eWhat is the significance of the IP protection class?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/23a833036c38e73146f5b96b6b9b626f7f117300.pdf?did=4169\u0026amp;pid=17828669\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSpec Sheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8eb999d4484c1155abefecfb932e458153df814d?did=4169\u0026amp;pid=17828669\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I use the data matrix code correctly?\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":48750886551807,"sku":"397780","price":414.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/5868\/6463\/files\/2ae32c943ed16ea841a3ed9fc70c7dbdbdde6c68-large_42e51a4d-5062-45ec-b6ee-ae7d9847dc97.png?v=1782717027","url":"https:\/\/hunkshome.com\/products\/brkr-3va41-1p-35a-65ka-ftfm-ld-lug","provider":"HunksHome®","version":"1.0","type":"link"}