{"product_id":"brkr-3va41-1p-50a-35ka-ftfm-ld-lug","title":"BRKR 3VA41 1P 50A 35KA FTFM LD LUG","description":"\u003ch2\u003eBRKR 3VA41 1P 50A 35KA FTFM LD LUG Molded Case Circuit Breaker\u003c\/h2\u003e\n\n\u003cp\u003eThis Siemens 3VA41 molded case circuit breaker is designed for reliable electrical protection in low voltage applications. It features a thermal-magnetic trip unit (TM210) with fixed overload (Ir) and short-circuit (Ii) protection, suitable for use by electrical distributors and switchgear suppliers. The breaker is rated for 50A current and provides medium (Class M) breaking capacity, making it appropriate for lighting solutions, wire and cable protection, and general electrical distribution.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufacturer: Siemens\u003c\/li\u003e\n  \u003cli\u003eManufacturer Part #: 3VA4150-5ED14-0AA0\u003c\/li\u003e\n  \u003cli\u003eNumber of Poles: 1\u003c\/li\u003e\n  \u003cli\u003eFrame Size: 3VA41\u003c\/li\u003e\n  \u003cli\u003eRated Current: 50 A\u003c\/li\u003e\n  \u003cli\u003eBreaking Capacity: 35 kA at 277 V, 14 kA at 600Y\/347 V\u003c\/li\u003e\n  \u003cli\u003eTrip Unit: Thermal-Magnetic TM210, fixed Ir and Ii\u003c\/li\u003e\n  \u003cli\u003eOperating Voltage (AC Rated): 480 V\u003c\/li\u003e\n  \u003cli\u003ePower Loss: 3.2 W per pole\u003c\/li\u003e\n  \u003cli\u003eMechanical Service Life: 15,000 operating cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical Endurance: 8,000 cycles at 480 V, 4,000 cycles at 600 V\u003c\/li\u003e\n  \u003cli\u003eConnection Type: Load side lugs installed only, output side circular conductor connection, infeed side low tab\u003c\/li\u003e\n  \u003cli\u003eConductor Size: 1 x (8 AWG - 3\/0) stranded conductor terminal\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 1.34 in x 5.31 in x 6.61 in\u003c\/li\u003e\n  \u003cli\u003eProtection Class IP: IP40 (front)\u003c\/li\u003e\n  \u003cli\u003eAmbient Operating Temperature: -25 °C to 70 °C\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.75 lbs (0.28 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit providing reliable overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eUL listed with HACR and HID type load switch designations\u003c\/li\u003e\n  \u003cli\u003eFixed trip settings for consistent protection (Ir = 50 A, Ii = 10 x In)\u003c\/li\u003e\n  \u003cli\u003eLugs installed on load side only to simplify installation\u003c\/li\u003e\n  \u003cli\u003eCompact design suitable for integration in switchgear and electrical distribution panels\u003c\/li\u003e\n  \u003cli\u003eHigh breaking capacity class M for medium duty applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads \u0026amp; Links\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/6cc1eb55c6e7bc0e7acbaf04e55746190f39ba1b.pdf?did=4169\u0026amp;pid=17828570\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e3D Image\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8a4547960986b04dfcc0e63d077619aa9e3060dd?did=4169\u0026amp;pid=17828570\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eShort-circuit current rating (SCCR) in industrial control panels?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/3a51979fc769d63fb6fa23eefc5e9aff0c4a736f?did=4169\u0026amp;pid=17828570\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eWhat is the significance of the IP protection class?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/33ed4c338b19c22ce14d34d214b1bc7557a14a19.pdf?did=4169\u0026amp;pid=17828570\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSpec Sheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8eb999d4484c1155abefecfb932e458153df814d?did=4169\u0026amp;pid=17828570\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I use the data matrix code correctly?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/f4c878d7ca1be3ee6cecfd481f027ab0716bfe62?did=4169\u0026amp;pid=17828570\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I compare devices in TIA-Selection-Tool?\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":48750887108863,"sku":"397633","price":303.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/5868\/6463\/files\/2ae32c943ed16ea841a3ed9fc70c7dbdbdde6c68-large_9ca737e3-f4a3-4d6b-9c65-284cdeace95f.png?v=1782717061","url":"https:\/\/hunkshome.com\/products\/brkr-3va41-1p-50a-35ka-ftfm-ld-lug","provider":"HunksHome®","version":"1.0","type":"link"}