{"product_id":"brkr-3va41-1p-50a-65ka-ftfm-ld-lug","title":"BRKR 3VA41 1P 50A 65KA FTFM LD LUG","description":"\u003ch2\u003eBRKR 3VA41 1P 50A 65KA FTFM LD LUG Molded Case Circuit Breaker\u003c\/h2\u003e\n\n\u003cp\u003eThe Siemens 3VA41 Frame 125 molded case circuit breaker is designed for reliable electrical protection in industrial and commercial applications. This 1-pole breaker features a thermal-magnetic trip unit (TM210) with fixed overload and short-circuit protection settings, suitable for use by electrical distributors and switchgear suppliers. It offers high breaking capacity for enhanced safety and is compatible with wire and cable sizes up to 8 AWG - 3\/0 stranded conductors. Ideal for lighting solutions and power distribution systems requiring robust overload and short-circuit protection.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufacturer: Siemens\u003c\/li\u003e\n  \u003cli\u003eManufacturer Part #: 3VA4150-6ED14-0AA0\u003c\/li\u003e\n  \u003cli\u003eFrame Size: 125\u003c\/li\u003e\n  \u003cli\u003eNumber of Poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated Current (In): 50 A\u003c\/li\u003e\n  \u003cli\u003eBreaking Capacity (UL 489): 65 kA at 277 V, 14 kA at 600Y\/347 V, 150 kA at 120 V, 25 kA at 347 V\u003c\/li\u003e\n  \u003cli\u003eTrip Unit: TM210 thermal-magnetic, fixed Ir and Ii\u003c\/li\u003e\n  \u003cli\u003eOperating Voltage: 415 V AC rated\u003c\/li\u003e\n  \u003cli\u003ePower Loss: 3.2 W per pole at rated current\u003c\/li\u003e\n  \u003cli\u003eMechanical Service Life: 15,000 operating cycles (typical)\u003c\/li\u003e\n  \u003cli\u003eElectrical Endurance: 8,000 cycles at 480 V, 4,000 cycles at 600 V\u003c\/li\u003e\n  \u003cli\u003eConnection Type: Low tab input side, circular conductor connection output side\u003c\/li\u003e\n  \u003cli\u003eConnectable Conductor Cross-Section: 1 x (8 AWG - 3\/0) stranded conductor\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 1 in x 5.09 in x 2.96 in (25.4 mm x 129.4 mm x 75.1 mm)\u003c\/li\u003e\n  \u003cli\u003eProtection Class: IP40 (front)\u003c\/li\u003e\n  \u003cli\u003eAmbient Operating Temperature Range: -25 ¬∞C to 70 ¬∞C\u003c\/li\u003e\n  \u003cli\u003eNet Weight: 0.28 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit providing fixed overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eHigh breaking capacity with class H rating for enhanced safety\u003c\/li\u003e\n  \u003cli\u003eDesigned for system protection in heating, air conditioning, and refrigeration circuits (HACR Type)\u003c\/li\u003e\n  \u003cli\u003eUL listed and certified for industrial and commercial use\u003c\/li\u003e\n  \u003cli\u003eCompact design suitable for space-constrained switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eLoad-side lug installation for simplified wiring\u003c\/li\u003e\n  \u003cli\u003eDurable construction with tin-plated connection surfaces for corrosion resistance\u003c\/li\u003e\n  \u003cli\u003eSuitable for use by electrical distributors and switchgear suppliers providing reliable wire and cable protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads \u0026amp; Links\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/3a51979fc769d63fb6fa23eefc5e9aff0c4a736f?did=4169\u0026amp;pid=17828015\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eWhat is the significance of the IP protection class?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/98de49fdc8f5b3dbe8181c407d68a8149777bb8f.pdf?did=4169\u0026amp;pid=17828015\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTechnical data sheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8eb999d4484c1155abefecfb932e458153df814d?did=4169\u0026amp;pid=17828015\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I use the data matrix code correctly?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8a4547960986b04dfcc0e63d077619aa9e3060dd?did=4169\u0026amp;pid=17828015\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eShort-circuit current rating (SCCR) in industrial control panels?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/f4c878d7ca1be3ee6cecfd481f027ab0716bfe62?did=4169\u0026amp;pid=17828015\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I compare devices in TIA-Selection-Tool?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/6cc1eb55c6e7bc0e7acbaf04e55746190f39ba1b.pdf?did=4169\u0026amp;pid=17828015\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e3D Image\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":48750887174399,"sku":"397757","price":414.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/5868\/6463\/files\/2ae32c943ed16ea841a3ed9fc70c7dbdbdde6c68-large_27dc8843-c2b9-4ec6-8cf5-772d945a0ef8.png?v=1782717064","url":"https:\/\/hunkshome.com\/products\/brkr-3va41-1p-50a-65ka-ftfm-ld-lug","provider":"HunksHome®","version":"1.0","type":"link"}