{"product_id":"brkr-3va41-1p-70a-35ka-ftfm-ld-lug","title":"BRKR 3VA41 1P 70A 35KA FTFM LD LUG","description":"\u003ch2\u003eBRKR 3VA41 1P 70A 35KA FTFM LD LUG Molded Case Circuit Breaker\u003c\/h2\u003e\n\n\u003cp\u003eThe Siemens 3VA41 1-pole molded case circuit breaker is designed for reliable electrical protection in commercial and industrial applications. This breaker is suitable for electrical distributors and switchgear suppliers requiring robust overload and short-circuit protection with a thermal-magnetic trip unit. It supports wire and cable connections with load-side lugs installed for secure terminal connections.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufacturer: Siemens\u003c\/li\u003e\n  \u003cli\u003eModel Number: 3VA4170-5ED14-0AA0\u003c\/li\u003e\n  \u003cli\u003eFrame Size: 3VA41 UL Frame 125\u003c\/li\u003e\n  \u003cli\u003eRated Operational Current: 70 A at 40 ¬∞C\u003c\/li\u003e\n  \u003cli\u003eNumber of Poles: 1\u003c\/li\u003e\n  \u003cli\u003eBreaking Capacity: 35 kA at 277 V, 14 kA at 600Y\/347 V, 85 kA at 120 V, 18 kA at 347 V\u003c\/li\u003e\n  \u003cli\u003eTrip Unit: TM210 thermal-magnetic with fixed Ir and Ii settings\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 1 in x 5.09 in x 2.96 in (25.4 mm x 129.4 mm x 75.1 mm)\u003c\/li\u003e\n  \u003cli\u003ePower Loss: 5.3 W per pole at rated current\u003c\/li\u003e\n  \u003cli\u003eMechanical Service Life: 15,000 operating cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical Endurance: 8,000 cycles at 480 V, 4,000 cycles at 600 V\u003c\/li\u003e\n  \u003cli\u003eConnection Type: Load side lugs only, circular conductor connection on output side, low tab on input side\u003c\/li\u003e\n  \u003cli\u003eConnectable Conductor Size: 1 x (8 AWG - 3\/0) stranded conductor\u003c\/li\u003e\n  \u003cli\u003eProtection Class: IP40 on the front\u003c\/li\u003e\n  \u003cli\u003eOperating Temperature Range: -25 ¬∞C to 70 ¬∞C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit (TM210) providing reliable overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eClass M breaking capacity for enhanced switching performance\u003c\/li\u003e\n  \u003cli\u003eFixed overload (Ir) and short-circuit (Ii) protection settings for consistent operation\u003c\/li\u003e\n  \u003cli\u003eCompact design optimized for integration in switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eLoad-side lug installation for secure and reliable wiring connections\u003c\/li\u003e\n  \u003cli\u003eCompliant with UL 489 standards for HACR-type circuit breakers\u003c\/li\u003e\n  \u003cli\u003eLow power loss for efficient operation\u003c\/li\u003e\n  \u003cli\u003eRobust mechanical and electrical endurance for long service life\u003c\/li\u003e\n  \u003cli\u003eSuitable for use in lighting solutions, wire and cable distribution, and as part of electrical distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads \u0026amp; Links\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/3a51979fc769d63fb6fa23eefc5e9aff0c4a736f?did=4169\u0026amp;pid=17826535\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eWhat is the significance of the IP protection class?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8a4547960986b04dfcc0e63d077619aa9e3060dd?did=4169\u0026amp;pid=17826535\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eShort-circuit current rating (SCCR) in industrial control panels?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/f4c878d7ca1be3ee6cecfd481f027ab0716bfe62?did=4169\u0026amp;pid=17826535\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I compare devices in TIA-Selection-Tool?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/2a233561683484b69eedfbe4d9f4287b308d9555.pdf?did=4169\u0026amp;pid=17826535\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSpec Sheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8eb999d4484c1155abefecfb932e458153df814d?did=4169\u0026amp;pid=17826535\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I use the data matrix code correctly?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/6cc1eb55c6e7bc0e7acbaf04e55746190f39ba1b.pdf?did=4169\u0026amp;pid=17826535\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e3D Image\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":48750888943871,"sku":"397637","price":332.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/5868\/6463\/files\/2ae32c943ed16ea841a3ed9fc70c7dbdbdde6c68-large_b626f609-5e81-4d95-8ce9-11881b5ba9b3.png?v=1782717082","url":"https:\/\/hunkshome.com\/products\/brkr-3va41-1p-70a-35ka-ftfm-ld-lug","provider":"HunksHome®","version":"1.0","type":"link"}