{"product_id":"brkr-3va41-2p-125a-35ka-ftfm-ld-lug","title":"BRKR 3VA41 2P 125A 35KA FTFM LD LUG","description":"\u003ch2\u003eBRKR 3VA41 2P 125A 35KA FTFM LD LUG Molded Case Circuit Breaker\u003c\/h2\u003e\n\n\u003cp\u003eThe Siemens 3VA41 molded case circuit breaker is designed for reliable electrical protection in industrial and commercial applications. It features a thermal-magnetic trip unit (TM210) with fixed overload and short-circuit settings, providing dependable line protection. This 2-pole breaker supports a rated operational current of 125A and is suitable for use by electrical distributors and switchgear suppliers requiring robust and precise circuit protection solutions.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufacturer: Siemens\u003c\/li\u003e\n  \u003cli\u003eManufacturer Part #: 3VA4112-5ED24-0AA0\u003c\/li\u003e\n  \u003cli\u003eNumber of Poles: 2\u003c\/li\u003e\n  \u003cli\u003eFrame Size: 3VA41\u003c\/li\u003e\n  \u003cli\u003eRated Current (In): 125 A\u003c\/li\u003e\n  \u003cli\u003eBreaking Capacity (IEC 60947 Class M): 35 kA at 480 V, 18 kA at 600Y\/347 V\u003c\/li\u003e\n  \u003cli\u003eOperating Voltage (AC): 415 V\u003c\/li\u003e\n  \u003cli\u003ePower Loss: 19.4 W maximum, 9.7 W per pole at rated current\u003c\/li\u003e\n  \u003cli\u003eMechanical Service Life: 15,000 operating cycles (typical)\u003c\/li\u003e\n  \u003cli\u003eElectrical Endurance: 8,000 cycles at 480 V, 4,000 cycles at 600 V\u003c\/li\u003e\n  \u003cli\u003eConnection Type: Low tab (infeed side), circular conductor connection (output side)\u003c\/li\u003e\n  \u003cli\u003eConnectable Conductor Size (Stranded): 1 x (8 AWG - 3\/0)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 2 in x 5.09 in x 2.96 in (50.8 mm x 129.4 mm x 75.1 mm)\u003c\/li\u003e\n  \u003cli\u003eProtection Class (Front): IP40\u003c\/li\u003e\n  \u003cli\u003eAmbient Operating Temperature: -25 ¬∞C to 70 ¬∞C\u003c\/li\u003e\n  \u003cli\u003eWeight: Approximately 0.514 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit TM210 with fixed overload (Ir=125 A) and short-circuit protection (Ii=10 x In)\u003c\/li\u003e\n  \u003cli\u003eClass M breaking capacity suitable for medium duty applications\u003c\/li\u003e\n  \u003cli\u003eHACR (Heating, Air Conditioning, and Refrigeration) rated circuit breaker\u003c\/li\u003e\n  \u003cli\u003eLoad side lugs installed for easy connection\u003c\/li\u003e\n  \u003cli\u003eUL Listed and compliant with UL 489 standards\u003c\/li\u003e\n  \u003cli\u003eNo auxiliary contacts or motor drive options included\u003c\/li\u003e\n  \u003cli\u003eRobust mechanical and electrical endurance for long service life\u003c\/li\u003e\n  \u003cli\u003eDesigned for use in wire and cable distribution and switchgear assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads \u0026amp; Links\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/2917c6a844ada933bdb153c675038d39b029aa4b.pdf?did=4169\u0026amp;pid=17827569\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTechnical data sheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/3a51979fc769d63fb6fa23eefc5e9aff0c4a736f?did=4169\u0026amp;pid=17827569\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eWhat is the significance of the IP protection class?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8a4547960986b04dfcc0e63d077619aa9e3060dd?did=4169\u0026amp;pid=17827569\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eShort-circuit current rating (SCCR) in industrial control panels?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8abb169ee318dea0ae9f3db53cd19597ee6b9cc1.pdf?did=4169\u0026amp;pid=17827569\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e3D Image\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8eb999d4484c1155abefecfb932e458153df814d?did=4169\u0026amp;pid=17827569\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I use the data matrix code correctly?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/f4c878d7ca1be3ee6cecfd481f027ab0716bfe62?did=4169\u0026amp;pid=17827569\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I compare devices in TIA-Selection-Tool?\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":48750891827455,"sku":"397716","price":1141.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/5868\/6463\/files\/1fba600ff388a520e4d2cbbf647df1a7535fefc7-large_4d1472b8-5590-4d98-8ebb-0e5ad9a0afb4.png?v=1782717141","url":"https:\/\/hunkshome.com\/products\/brkr-3va41-2p-125a-35ka-ftfm-ld-lug","provider":"HunksHome®","version":"1.0","type":"link"}