{"product_id":"brkr-3va41-2p-70a-25ka-ftfm-nav-ld-lug","title":"BRKR 3VA41 2P 70A 25KA FTFM NAV LD LUG","description":"\u003ch2\u003eBRKR 3VA41 2P 70A 25KA Molded Case Circuit Breaker\u003c\/h2\u003e\n\n\u003cp\u003eThe Siemens 3VA41 2-pole molded case circuit breaker is designed for reliable electrical protection in low voltage applications. It is suitable for use by electrical distributors and switchgear suppliers requiring high breaking capacity and thermal-magnetic trip protection. This device is ideal for lighting solutions, wire and cable protection, and system protection in commercial and industrial electrical installations.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufacturer: Siemens\u003c\/li\u003e\n  \u003cli\u003eModel Number: 3VA4170-4ED24-1AA0\u003c\/li\u003e\n  \u003cli\u003eFrame Size: 125 (3VA41)\u003c\/li\u003e\n  \u003cli\u003eNumber of Poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated Current (In): 70 A\u003c\/li\u003e\n  \u003cli\u003eBreaking Capacity: 25 kA at 480 V, 14 kA at 600Y\/347 V\u003c\/li\u003e\n  \u003cli\u003eTrip Unit: TM210 Thermal-Magnetic, fixed Ir and Ii\u003c\/li\u003e\n  \u003cli\u003eOperational Voltage: 480 V AC\u003c\/li\u003e\n  \u003cli\u003ePower Loss: 10.7 W maximum, 5.35 W per pole at rated current\u003c\/li\u003e\n  \u003cli\u003eMechanical Service Life: 15,000 operating cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical Endurance: 8,000 cycles at 480 V, 4,000 cycles at 600 V\u003c\/li\u003e\n  \u003cli\u003eConnection Type: Load side lugs installed only, tin-plated circular conductor connection\u003c\/li\u003e\n  \u003cli\u003eConnectable Conductor Size: 1 x (8 AWG - 3\/0) stranded conductor\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 2 in x 5.09 in x 2.96 in (50.8 mm x 129.4 mm x 75.1 mm)\u003c\/li\u003e\n  \u003cli\u003eWeight: Approximately 0.514 kg (1.31 lbs)\u003c\/li\u003e\n  \u003cli\u003eProtection Class: IP40 (front)\u003c\/li\u003e\n  \u003cli\u003eAmbient Operating Temperature: -25 ¬∞C to 70 ¬∞C\u003c\/li\u003e\n  \u003cli\u003eCertifications: UL 489 SB Naval Rated, UL Listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit providing overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eFixed overload (Ir) and short-circuit (Ii) protection settings for consistent performance\u003c\/li\u003e\n  \u003cli\u003eClass S breaking capacity suitable for demanding industrial applications\u003c\/li\u003e\n  \u003cli\u003eNaval rated for operation at 50 ¬∞C ambient temperature\u003c\/li\u003e\n  \u003cli\u003eLoad side lug installation simplifies wiring and enhances safety\u003c\/li\u003e\n  \u003cli\u003eCompact design optimized for space-saving switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eRobust mechanical and electrical endurance for long service life\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads \u0026amp; Links\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/5f2e45a839af8cc50e0a856380b4ba53ff1771ec.pdf?did=4169\u0026amp;pid=17828920\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e3D Image\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8eb999d4484c1155abefecfb932e458153df814d?did=4169\u0026amp;pid=17828920\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I use the data matrix code correctly?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/f4c878d7ca1be3ee6cecfd481f027ab0716bfe62?did=4169\u0026amp;pid=17828920\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I compare devices in TIA-Selection-Tool?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/cea6e2c6723cc8310c6feb91baad477a81d31e97.pdf?did=4169\u0026amp;pid=17828920\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSpec Sheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8a4547960986b04dfcc0e63d077619aa9e3060dd?did=4169\u0026amp;pid=17828920\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eShort-circuit current rating (SCCR) in industrial control panels?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/3a51979fc769d63fb6fa23eefc5e9aff0c4a736f?did=4169\u0026amp;pid=17828920\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eWhat is the significance of the IP protection class?\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":48750897529087,"sku":"396603","price":570.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/5868\/6463\/files\/ef1c728c96e003c5c21bb94adc0e046800e96b98-large_ba3da78d-5cc1-4def-af46-d185b817db3d.png?v=1782717255","url":"https:\/\/hunkshome.com\/products\/brkr-3va41-2p-70a-25ka-ftfm-nav-ld-lug","provider":"HunksHome®","version":"1.0","type":"link"}