{"product_id":"brkr-3va41-2p-90a-25ka-ftfm-nav-ld-lug","title":"BRKR 3VA41 2P 90A 25KA FTFM NAV LD LUG","description":"\u003ch2\u003eBRKR 3VA41 2P 90A 25KA FTFM NAV LD LUG Molded Case Circuit Breaker\u003c\/h2\u003e\n\n\u003cp\u003eThe Siemens 3VA41 2-pole molded case circuit breaker is designed for reliable electrical protection in industrial and commercial applications. This low voltage breaker features a thermal-magnetic trip unit (TM210) with fixed overload (Ir) and short-circuit (Ii) settings, suitable for use by electrical distributors and switchgear suppliers requiring robust protection for wire and cable circuits. It is naval rated for operation at 50¬∞C, supporting demanding environments.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufacturer: Siemens\u003c\/li\u003e\n  \u003cli\u003eManufacturer Part #: 3VA4190-4ED24-1AA0\u003c\/li\u003e\n  \u003cli\u003eFrame Size: 125 (3VA41)\u003c\/li\u003e\n  \u003cli\u003eNumber of Poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated Current: 90 A\u003c\/li\u003e\n  \u003cli\u003eBreaking Capacity: 25 kA at 480 V, 14 kA at 600Y\/347 V\u003c\/li\u003e\n  \u003cli\u003eTrip Unit: TM210 Thermal-Magnetic, fixed Ir and Ii\u003c\/li\u003e\n  \u003cli\u003eOperating Voltage: 415 V AC rated\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 2.28 in x 5.31 in x 6.61 in\u003c\/li\u003e\n  \u003cli\u003eWeight: 1.31 lb (0.514 kg)\u003c\/li\u003e\n  \u003cli\u003eConnection Type: Load side lugs installed, tin-plated low tab terminals\u003c\/li\u003e\n  \u003cli\u003eProtection Class: IP40 on front\u003c\/li\u003e\n  \u003cli\u003eOperating Temperature Range: -25¬∞C to 70¬∞C\u003c\/li\u003e\n  \u003cli\u003eUL Listed: UL489 SB (Naval rated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit provides reliable overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eClass S breaking capacity for enhanced switching performance\u003c\/li\u003e\n  \u003cli\u003eNaval rating supports operation in environments up to 50¬∞C\u003c\/li\u003e\n  \u003cli\u003eCompact design suitable for space-conscious switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eLoad side lug connections simplify wiring installation\u003c\/li\u003e\n  \u003cli\u003eMechanical service life of approximately 15,000 operating cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance of up to 8,000 cycles at 480 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads \u0026amp; Links\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/f4c878d7ca1be3ee6cecfd481f027ab0716bfe62?did=4169\u0026amp;pid=17827523\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I compare devices in TIA-Selection-Tool?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8a4547960986b04dfcc0e63d077619aa9e3060dd?did=4169\u0026amp;pid=17827523\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eShort-circuit current rating (SCCR) in industrial control panels?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/a28c435b073d2cc672da22997d3043cef790a623.pdf?did=4169\u0026amp;pid=17827523\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTechnical data sheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8eb999d4484c1155abefecfb932e458153df814d?did=4169\u0026amp;pid=17827523\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I use the data matrix code correctly?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/600a963c27a58790458418b0c7fc78a6b40dba51?did=4169\u0026amp;pid=17827523\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eREACH information\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/3a51979fc769d63fb6fa23eefc5e9aff0c4a736f?did=4169\u0026amp;pid=17827523\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eWhat is the significance of the IP protection class?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/5f2e45a839af8cc50e0a856380b4ba53ff1771ec.pdf?did=4169\u0026amp;pid=17827523\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e3D Image\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":48750898544895,"sku":"396585","price":570.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/5868\/6463\/files\/ef1c728c96e003c5c21bb94adc0e046800e96b98-large_65e8b462-dfe9-44f9-82a6-3bc333dd0165.png?v=1782717275","url":"https:\/\/hunkshome.com\/products\/brkr-3va41-2p-90a-25ka-ftfm-nav-ld-lug","provider":"HunksHome®","version":"1.0","type":"link"}