{"product_id":"brkr-3va41-3p-30a-25ka-ftfm-ld-lug","title":"BRKR 3VA41 3P 30A 25KA FTFM LD LUG","description":"\u003ch2\u003eBRKR 3VA41 3P 30A 25KA FTFM LD LUG Molded Case Circuit Breaker\u003c\/h2\u003e\n\n\u003cp\u003eThe Siemens BRKR 3VA41 3P 30A molded case circuit breaker is designed for reliable system protection in low voltage electrical distribution. It is suitable for use in electrical distributor applications, lighting solutions, wire and cable protection, and as part of switchgear assemblies. This 3-pole breaker features a thermal-magnetic trip unit with fixed overload and short-circuit protection, providing secure interruption of electrical faults in commercial and industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufacturer: Siemens\u003c\/li\u003e\n  \u003cli\u003eManufacturer Part #: 3VA4130-4ED34-0AA0\u003c\/li\u003e\n  \u003cli\u003eFrame Size: 3VA41 (UL Frame 125)\u003c\/li\u003e\n  \u003cli\u003ePoles: 3\u003c\/li\u003e\n  \u003cli\u003eRated Current: 30 A\u003c\/li\u003e\n  \u003cli\u003eBreaking Capacity at 480 V: 25 kA (Class S)\u003c\/li\u003e\n  \u003cli\u003eBreaking Capacity at 600Y\/347 V: 14 kA\u003c\/li\u003e\n  \u003cli\u003eOverload Protection: Fixed Ir = 30 A\u003c\/li\u003e\n  \u003cli\u003eShort-Circuit Protection: Fixed Ii = 10 x In\u003c\/li\u003e\n  \u003cli\u003eTrip Unit: TM210 Thermal-Magnetic\u003c\/li\u003e\n  \u003cli\u003eOperating Voltage (Rated): 690 V AC\u003c\/li\u003e\n  \u003cli\u003ePower Loss: Maximum 9 W, 3 W per pole at rated current\u003c\/li\u003e\n  \u003cli\u003eMechanical Service Life: 15,000 operating cycles (typical)\u003c\/li\u003e\n  \u003cli\u003eElectrical Endurance: 8,000 cycles at 480 V, 4,000 cycles at 600 V\u003c\/li\u003e\n  \u003cli\u003eConnection Type: Load side lugs installed, tin-plated circular conductor connection on output side, low tab on input side\u003c\/li\u003e\n  \u003cli\u003eConnectable Conductor Size: 14 AWG to 8 AWG stranded\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 5.31 in x 3.46 in x 6.30 in\u003c\/li\u003e\n  \u003cli\u003eWeight: 1.83 lbs (0.743 kg)\u003c\/li\u003e\n  \u003cli\u003eProtection Class (Front): IP40\u003c\/li\u003e\n  \u003cli\u003eAmbient Operating Temperature Range: -25 ¬∞C to 70 ¬∞C\u003c\/li\u003e\n  \u003cli\u003eUL Listed: Yes (UL 489 compliant, HACR and HID rated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit provides combined overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eFixed response values for reliable and consistent protection settings\u003c\/li\u003e\n  \u003cli\u003eLoad side lugs pre-installed for simplified wiring\u003c\/li\u003e\n  \u003cli\u003eDesigned for system protection in HVAC and lighting control applications\u003c\/li\u003e\n  \u003cli\u003eCompatible with standard electrical distribution equipment and switchgear\u003c\/li\u003e\n  \u003cli\u003eRobust mechanical and electrical endurance for long service life\u003c\/li\u003e\n  \u003cli\u003eCompact design for space-saving panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads \u0026amp; Links\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8eb999d4484c1155abefecfb932e458153df814d?did=4169\u0026amp;pid=17827852\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I use the data matrix code correctly?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/3a51979fc769d63fb6fa23eefc5e9aff0c4a736f?did=4169\u0026amp;pid=17827852\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eWhat is the significance of the IP protection class?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/55267cecf6a45c5574e838a278b3b3cc5a99820c.pdf?did=4169\u0026amp;pid=17827852\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e3D Image\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/c865e5c6b477de026a584e31c9932f2d92830576.pdf?did=4169\u0026amp;pid=17827852\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTechnical data sheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/f4c878d7ca1be3ee6cecfd481f027ab0716bfe62?did=4169\u0026amp;pid=17827852\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I compare devices in TIA-Selection-Tool?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8a4547960986b04dfcc0e63d077619aa9e3060dd?did=4169\u0026amp;pid=17827852\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eShort-circuit current rating (SCCR) in industrial control panels?\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":48750901428479,"sku":"396614","price":525.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/5868\/6463\/files\/42413be762f060d5e90a732644902cb1f09e2577-large_361ec22b-8d9d-40ed-819a-15cb9bf0e97d.png?v=1782717351","url":"https:\/\/hunkshome.com\/products\/brkr-3va41-3p-30a-25ka-ftfm-ld-lug","provider":"HunksHome®","version":"1.0","type":"link"}