{"product_id":"brkr-3va41-3p-60a-25ka-ftfm-nav-ld-lug","title":"BRKR 3VA41 3P 60A 25KA FTFM NAV LD LUG","description":"\u003ch2\u003eBRKR 3VA41 3P 60A 25KA FTFM NAV LD LUG Molded Case Circuit Breaker\u003c\/h2\u003e\n\n\u003cp\u003eThe Siemens 3VA41 molded case circuit breaker is designed for reliable system protection in low voltage electrical distribution. It features a 3-pole configuration with a 60A rating and a thermal-magnetic trip unit, suitable for applications requiring robust overload and short-circuit protection. This breaker is ideal for electrical distributors and switchgear suppliers looking for a UL-listed device with naval rating and high breaking capacity for commercial and industrial lighting solutions and wire and cable systems.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufacturer: Siemens\u003c\/li\u003e\n  \u003cli\u003eManufacturer Part #: 3VA4160-4ED34-1AA0\u003c\/li\u003e\n  \u003cli\u003eFrame Size: 3VA41 (UL Frame 125)\u003c\/li\u003e\n  \u003cli\u003eCurrent Rating: 60 A\u003c\/li\u003e\n  \u003cli\u003eNumber of Poles: 3\u003c\/li\u003e\n  \u003cli\u003eBreaking Capacity: 25 kA at 480 V\u003c\/li\u003e\n  \u003cli\u003eBreaking Capacity: 14 kA at 600Y\/347 V\u003c\/li\u003e\n  \u003cli\u003eTrip Unit: TM210 Thermal-Magnetic, Fixed Ir and Ii\u003c\/li\u003e\n  \u003cli\u003eRated Operating Voltage: 600 V AC\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 5.31 in x 3.46 in x 6.30 in\u003c\/li\u003e\n  \u003cli\u003eWeight: 1.83 lbs (0.743 kg)\u003c\/li\u003e\n  \u003cli\u003eUL Listed: UL 489 SB (Naval rated, 50 ¬∞C)\u003c\/li\u003e\n  \u003cli\u003eConnection Type: Load side lugs installed only, tin-plated circular conductor connection (output side), low tab connection (input side)\u003c\/li\u003e\n  \u003cli\u003eProtection Class: IP40 (front)\u003c\/li\u003e\n  \u003cli\u003eOperating Temperature Range: -25 ¬∞C to 70 ¬∞C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit provides reliable overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eClass S breaking capacity ensures high interrupting performance\u003c\/li\u003e\n  \u003cli\u003eNaval rating suitable for harsh environments up to 50 ¬∞C\u003c\/li\u003e\n  \u003cli\u003eCompact design for efficient space utilization in switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eLoad side lug installation simplifies wiring and maintenance\u003c\/li\u003e\n  \u003cli\u003eUL listed for HACR (Heating, Air Conditioning, and Refrigeration) applications\u003c\/li\u003e\n  \u003cli\u003eRobust mechanical and electrical endurance with up to 15,000 mechanical cycles and 8,000 electrical cycles at 480 V\u003c\/li\u003e\n  \u003cli\u003eCompatible with standard wire sizes from 8 AWG to 3\/0 stranded conductors\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads \u0026amp; Links\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8a4547960986b04dfcc0e63d077619aa9e3060dd?did=4169\u0026amp;pid=17828779\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eShort-circuit current rating (SCCR) in industrial control panels?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/f4c878d7ca1be3ee6cecfd481f027ab0716bfe62?did=4169\u0026amp;pid=17828779\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I compare devices in TIA-Selection-Tool?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/1072268ab8991b51818e1a6076c353f3717f0f94.pdf?did=4169\u0026amp;pid=17828779\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e3D Image\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/3a51979fc769d63fb6fa23eefc5e9aff0c4a736f?did=4169\u0026amp;pid=17828779\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eWhat is the significance of the IP protection class?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/8eb999d4484c1155abefecfb932e458153df814d?did=4169\u0026amp;pid=17828779\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHow do I use the data matrix code correctly?\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/262\/csv_siemens\/5f3ce270cfc38cebda1fe6eb9531026f1241f52e.pdf?did=4169\u0026amp;pid=17828779\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSpec Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":48750903165183,"sku":"396598","price":552.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0805\/5868\/6463\/files\/0dad480888705e1e6975e2acd29bf0f036172ef7-large_5b100262-634e-44e3-9bab-4f832cf1e0be.png?v=1782717409","url":"https:\/\/hunkshome.com\/products\/brkr-3va41-3p-60a-25ka-ftfm-nav-ld-lug","provider":"HunksHome®","version":"1.0","type":"link"}